Proudly Serving Charlottesville & Surrounding Areas
 

 

Job completed for Allie & Miles R.

Completion date: February 12, 2018

Location: Warrenton, VA

Why did the customer contact us?

Customer asked us to replace the thermostat in the home.

Solutions provided:

After replacing the thermostat, discovered that the gas furnace was going into a soft lockout after only a short run time. We timed it at 3 minutes. Found the unit was tripping on a high limit switch located on the primary heat exchanger. Inspected all the ductwork, verified duct sizing, and layout. Everything started to point to a dirty/clogged heat exchanger. We pulled the blower housing and found the secondary heat exchanger to be really dirty. Carefully tried to remove as much debris as possible, to see if we could make some improvement to the system. It changed our total run time from 3 minutes to 5 minutes. The unit still went to a lockout. The Furnace had been run with the improper filter during renovations. The secondary heat exchanger is not covered under the manufacturer's warranty due to failure to maintain the system. The manufacturer states that if the secondary heat exchanger is dirty that it cannot be cleaned and needs to be replaced. Which is over a $2000.00 repair. This is an example of why we stress bi-annual maintenance.

Team members on this project:

Alex Laukaitis

Photos & Videos:

Heat Exchanger After Attempted Cleaning of the Heat Exchanger. Surface debris is now gone, but the fins inside are still clogged.
Large View Icon
Heat Exchanger After Attempted Cleaning of the Heat Exchanger. Surface debris is now gone, but the fins inside are still clogged.
Clogged Heat Exchanger
Large View Icon
Clogged Heat Exchanger
Clogged Heat Exchanger
Large View Icon
Clogged Heat Exchanger
Return Plenum
Large View Icon
Return Plenum